Millaa Millaa Falls, Queensland, Australia

NuKorc Fresh Technical Information

Specifications

NuKorc's'Fresh' closures are offered with two densities, Reference 1 at 45% and reference 2 at 41%. 'Fresh' closures offer the similar snap-back performance to Nukorc closures however take a greater compression set, and upon extraction this enables ease of re-insertion. For this reason, 'Fresh' require no chamfer.

Leaker Test

Ref 1 & Ref 2 'Fresh' closures were bottled with headspace 15mm, sample sets subjected to 24 hours at 35°C / 24 hours at 18°C / 24 hours at 5°C respectively. All samples demonstrated no sign of leaking or turning & closures were extracted within the specified force range.

Diameter

Taken from two different points on the closure, diameter consistency impacts upon both extraction force & OTR. The figures below demonstrate approximately 0.2mm variance in diameter across the sample population.

Sample Size Mean (mm) Standard Dev (mm) Tolerance (mm)
Ref 1 50 21.84 0.21 21.6 - 22.4
Ref 2 50 21.88 0.17 21.6 - 22.4

Length

Consistency of length is demonstrated, with approximately 0.1mm variance in length across the sample population.

Sample Size Mean (mm) Standard Dev (mm) Tolerance (mm)
Ref 1 50 37.07 0.10 37.0 - 37.4
Ref 2 50 37.02 0.08 37.0 - 37.4

Ovality

Ovality may impact upon extraction force. The figures below demonstrate approximately a mean ovality of approximately 0.4mm.

Sample Size Mean (mm) Standard Dev (mm) Tolerance (mm)
Ref 1 50 0.36 0.11 ≤0.8
Ref 2 50 0.38 0.12 ≤0.8

Weight

Consistency in weight is important to ensure a consistent closure density, which in turn may impact upon OTR.

Sample Size Mean (g) Standard Dev (g) Tolerance (g)
Ref 1 50 6.16 0.04 5.9 - 6.4
Ref 2 50 5.64 0.10 5.3 - 5.8

Length

Consistency of length is demonstrated, with approximately 0.1mm variance in length across the sample population.

Sample Size Mean (mm) Standard Dev (mm) Tolerance (mm)
Ref 1 50 37.07 0.10 37.0 - 37.4
Ref 2 50 37.02 0.08 37.0 - 37.4

Density

Consistency of length is demonstrated, with approximately 0.1mm variance in length across the sample population.

Sample Size Mean (%) Standard Dev (%) Tolerance (%)
Ref 1 50 44.09 0.81 42 - 46
Ref 2 50 41.10 0.22 40 - 42

Extraction Force

Extraction force is a measure of the force require dot remove closure form bottle. 30kg-force is the existing Nukorc target.

Sample Size Mean (kg) Standard Dev (kg) Tolerance (kg)
Ref 1 50 26.65 3.53 20 - 40
Ref 2 50 27.81 1.66 20 - 40

Off Corkscrew Torque (OCS)

Off corkscrew torque is a measure of the force required to remove the closure from the corkscrew. Nukorc specification range is 0.5 - 0.9 Nm..

Sample Size Mean (Nm) Standard Dev (Nm) Tolerance (Nm)
Ref 1 50 0.66 0.07 0.5 - 0.8
Ref 2 50 0.64 0.08 0.5 - 0.8

Rebound (Compression Set) - after 6 months in bottle

Rebound is related to the re-insertion capabilities of the closure. A slower rebound rate will provide ease of re-insertion into bottle after opening.

Ref 2 Sample Size Mean (%) Standard Dev (%) Re-insertion
0 10 92.09 0.67 NA
5 mins 10 92.55 0.51 Easy
10 mins 10 92.86 0.44 Moderate
30 mins 10 92.93 0.40 Moderate

Oxygen Transmission Rate

OTR is the measure of oxygen ingress through the closure. Low rates are desirable as oxygen transmission into wine will result in oxidation of the wine.

Brand Dimensions (mm) Density (%) OTR cc O2 / Closure per Day
'Fresh' 37x22 41 0.012
NuKorc 40x22 45 0.012